Artículo en Inglés | MEDLINE | ID: mdl-38613562

RESUMEN

PURPOSE: Using diagnostic computed tomography (dCT) scans instead of CT simulation (CTsim) scans can increase departmental efficiency and reduce patient burden. The goal of the DART trial was to assess the efficacy and acceptability of dCT-based planning workflows with a focus on patient experiences, plan deliverability and adequacy of target coverage, and workflows. METHODS AND MATERIALS: Patients undergoing same-day CTsim and treatment for palliative radiation therapy to thoracic, abdominopelvic, or proximal limb targets with a recent dCT (within 28 days) in a reproducible position were eligible. After stratifying by target type (bone or soft tissue vs. visceral), participants were randomized (1:2 ratio) between CTsim-based (CTsim arm) vs. dCT-based planning (dCT arm). The primary endpoint was time in center (TIC), defined as total time spent in the cancer center on first day of treatment, from first radiation department appointment to first fraction completion. Secondary endpoints included plan deliverability, adequacy of target coverage, and stakeholder acceptability. RESULTS: Thirty-three patients (42 treatment sites) were enrolled between June 2022 and April 2023. The median age was 72 (interquartile range [IQR]: 67-78), 73% were male, and the most common primary cancers were lung (33%), prostate (24%), and breast (12%). The most common dose and fractionations were 8 Gy in 1 and 20 Gy in 5 fractions (50% and 43% of plans, respectively). TIC was 4.7 ± 1.1 hours (mean ± SD) in the CTsim arm vs. 0.41 ± 0.14 hours in the dCT arm (P < .001). All dCT plans were deliverable. All plans in both arms were rated as "acceptable" (80% CTsim; 81% dCT) or "acceptable with minor deviation" (20% CTsim; 19% dCT). Patient perception of acceptability was similar in both arms with the exception of time burden, which was rated as "acceptable" by 50% in the CTsim arm vs. 90% in the dCT arm (P = .025). CONCLUSION: dCT-based radiation planning substantially reduced TIC without detriment in plan deliverability or quality and had a tangible impact on patient experience with reduced patient-reported time burden.

2.
Sci Rep ; 14(1): 2719, 2024 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-38302542

RESUMEN

Hand-arm vibration injury is a well-known occupational disorder that affects many workers globally. The diagnosis is based mainly on quantitative psychophysical tests and medical history. Typical manifestations of hand-arm vibration injury entail episodes of finger blanching, Raynaud's phenomenon (RP) and sensorineural symptoms from affected nerve fibres and mechanoreceptors in the skin. Differences in serum levels of 17 different biomarkers between 92 patients with hand-arm vibration injury and 51 controls were analysed. Patients with hand-arm vibration injury entailing RP and sensorineural manifestations showed elevated levels of biomarkers associated with endothelial injury or dysfunction, inflammation, vaso- or neuroprotective compensatory, or apoptotic mechanisms: intercellular adhesion molecule-1 (ICAM-1), monocyte chemoattractant protein-1 (MCP-1); thrombomodulin (TM), heat shock protein 27 (HSP27); von Willebrand factor, calcitonin gene-related peptide (CGRP) and caspase-3. This study adds important knowledge on pathophysiological mechanisms that can contribute to the implementation of a more objective method for diagnosis of hand-arm vibration injury.


Asunto(s)
Traumatismos del Brazo , Traumatismos de la Mano , Enfermedades Profesionales , Enfermedad de Raynaud , Humanos , Vibración , Mano , Dedos/inervación , Biomarcadores
3.
Eur Urol Oncol ; 7(1): 147-150, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37487813

RESUMEN

Stereotactic magnetic resonance (MR)-guided adaptive radiotherapy (SMART) for renal cell carcinoma may result in more precise treatment delivery through the capabilities for improved image quality, daily adaptive planning, and accounting for respiratory motion during treatment with real-time MR tracking. In this study, we aimed to characterize the safety and feasibility of SMART for localized kidney cancer. Twenty patients with localized kidney cancer (ten treated in a prospective phase 1 trial and ten in the supplemental cohort) were treated to 40 Gy in five fractions on a 0.35 T MR-guided linear accelerator with daily adaptive planning and a cine MR-guided inspiratory breath hold technique. The median follow-up time was 17 mo (interquartile range: 13-20 months). A single patient developed local failure at 30 mo. No grade ≥3 adverse events were reported. The mean decrease in estimated glomerular filtration rate was -1.8 ml/min/1.73 m2 (95% confidence interval or CI [-6.6 to 3.1 ml/min/1.73 m2]), and the mean decrease in tumor diameter was -0.20 cm (95% CI [-0.6 to 0.2 cm]) at the last follow-up. Anterior location and overlap of the 25 or 28 Gy isodose line with gastrointestinal organs at risk were predictive of the benefit from online adaptive planning. Kidney SMART is feasible and, at the early time point evaluated in this study, was well tolerated with minimal decline in renal function. More studies are warranted to further evaluate the safety and efficacy of this technique. PATIENT SUMMARY: For patients with localized renal cell carcinoma who are not surgical candidates, stereotactic magnetic resonance--guided adaptive radiotherapy is a feasible and safe noninvasive treatment option that results in minimal impact on kidney function.


Asunto(s)
Carcinoma de Células Renales , Neoplasias Renales , Radiocirugia , Humanos , Carcinoma de Células Renales/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Estudios Prospectivos , Radiocirugia/métodos , Neoplasias Renales/radioterapia , Riñón , Espectroscopía de Resonancia Magnética
4.
Radiother Oncol ; 190: 110034, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38030080

RESUMEN

BACKGROUND/PURPOSE: Central/ultra-central thoracic tumors are challenging to treat with stereotactic radiotherapy due potential high-grade toxicity. Stereotactic MR-guided adaptive radiation therapy (SMART) may improve the therapeutic window through motion control with breath-hold gating and real-time MR-imaging as well as the option for daily online adaptive replanning to account for changes in target and/or organ-at-risk (OAR) location. MATERIALS/METHODS: 26 central (19 ultra-central) thoracic oligoprogressive/oligometastatic tumors treated with isotoxic (OAR constraints-driven) 5-fraction SMART (median 50 Gy, range 35-60) between 10/2019-10/2022 were reviewed. Central tumor was defined as tumor within or touching 2 cm around proximal tracheobronchial tree (PBT) or adjacent to mediastinal/pericardial pleura. Ultra-central was defined as tumor abutting the PBT, esophagus, or great vessel. Hard OAR constraints observed were ≤ 0.03 cc for PBT V40, great vessel V52.5, and esophagus V35. Local failure was defined as tumor progression/recurrence within the planning target volume. RESULTS: Tumor abutted the PBT in 31 %, esophagus in 31 %, great vessel in 65 %, and heart in 42 % of cases. 96 % of fractions were treated with reoptimized plan, necessary to meet OAR constraints (80 %) and/or target coverage (20 %). Median follow-up was 19 months (27 months among surviving patients). Local control (LC) was 96 % at 1-year and 90 % at 2-years (total 2/26 local failure). 23 % had G2 acute toxicities (esophagitis, dysphagia, anorexia, nausea) and one (4 %) had G3 acute radiation dermatitis. There were no G4-5 acute toxicities. There was no symptomatic pneumonitis and no G2 + late toxicities. CONCLUSION: Isotoxic 5-fraction SMART resulted in high rates of LC and minimal toxicity. This approach may widen the therapeutic window for high-risk oligoprogressive/oligometastatic thoracic tumors.


Asunto(s)
Neoplasias Pulmonares , Traumatismos por Radiación , Radiocirugia , Neoplasias Torácicas , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Recurrencia Local de Neoplasia , Radiocirugia/métodos , Neoplasias Torácicas/radioterapia , Imagen por Resonancia Magnética/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/patología
5.
Theranostics ; 13(14): 4711-4729, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37771768

RESUMEN

Background: The introduction of magnetic resonance (MR)-guided radiation treatment planning has opened a new space for theranostic nanoparticles to reduce acute toxicity while improving local control. In this work, second-generation AGuIX® nanoparticles (AGuIX-Bi) are synthesized and validated. AGuIX-Bi are shown to maintain MR positive contrast while further amplifying the radiation dose by the replacement of some Gd3+ cations with higher Z Bi3+. These next-generation nanoparticles are based on the AGuIX® platform, which is currently being evaluated in multiple Phase II clinical trials in combination with radiotherapy. Methods: In this clinically scalable methodology, AGuIX® is used as an initial chelation platform to exchange Gd3+ for Bi3+. AGuIX-Bi nanoparticles are synthesized with three ratios of Gd/Bi, each maintaining MR contrast while further amplifying radiation dose relative to Bi3+. Safety, efficacy, and theranostic potential of the nanoparticles were evaluated in vitro and in vivo in a human non-small cell lung cancer model. Results: We demonstrated that increasing Bi3+ in the nanoparticles is associated with more DNA damage and improves in vivo efficacy with a statistically significant delay in tumor growth and 33% complete regression for the largest Bi/Gd ratio tested. The addition of Bi3+ by our synthetic method leads to nanoparticles that present slightly altered pharmacokinetics and lengthening of the period of high tumor accumulation with no observed evidence of toxicity. Conclusions: We confirmed the safety and enhanced efficacy of AGuIX-Bi with radiation therapy at the selected ratio of 30Gd/70Bi. These results provide crucial evidence towards patient translation.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Nanopartículas , Humanos , Medicina de Precisión , Medios de Contraste , Imagen por Resonancia Magnética/métodos , Dosis de Radiación , Nanomedicina Teranóstica/métodos
6.
Vet Radiol Ultrasound ; 64(3): 402-410, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36727204

RESUMEN

Ruptures of pulmonary blebs and bullae are the most common cause of spontaneous pneumothorax in dogs. Incidental bullae/blebs have been documented in otherwise healthy people, however information for veterinary patients is currently lacking. Objectives of this retrospective, observer agreement, analytical study were to characterize incidental bullae in thoracic CT studies of dogs, assess interobserver variability for characterizing the bullae, and assess anesthesia risks. Inclusion criteria were dogs presenting for non-pneumothorax related reasons that had a thoracic CT at a single specialty and emergency hospital from 2012 to 2021 and had a bulla listed in the CT report. Medical records for dogs meeting inclusion criteria were reviewed to collect data on signalment, weight, total number of general anesthesia procedures 2 years prior and 2 years following the CT scan, and adverse anesthesia events. In addition, the CT images were reviewed by three American College of Veterinary Radiology-certified veterinary radiologists to collect data on the location, size, number of bullae and thickness of the bulla wall. A total of 1119 dogs met initial inclusion criteria and 74 dogs were included in analyses. There was no sex predilection for incidental pulmonary bullae. Bullae were more commonly found in older (median age 11.3 years), large breed dogs (median weight 20.7 kg). A solitary bulla of less than 1 cm was the most common finding with no apparent predilection for a particular lung lobe. There was strong correlation among the three radiologists for bulla location, size, and number, but weak correlations for bulla wall thickness. No adverse anesthesia events were found following CT anesthesia or following repetitive anesthesia procedures.


Asunto(s)
Vesícula , Enfermedades de los Perros , Perros , Animales , Vesícula/diagnóstico por imagen , Vesícula/etiología , Vesícula/veterinaria , Estudios Retrospectivos , Variaciones Dependientes del Observador , Tomografía Computarizada por Rayos X/efectos adversos , Tomografía Computarizada por Rayos X/veterinaria , Anestesia General/efectos adversos , Anestesia General/veterinaria , Enfermedades de los Perros/diagnóstico por imagen , Enfermedades de los Perros/epidemiología , Enfermedades de los Perros/etiología
8.
Adv Radiat Oncol ; 7(5): 100934, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35847547

RESUMEN

Purpose: Stereotactic magnetic resonance (MR)-guided adaptive radiation therapy (SMART) for prostate cancer allows for MR-based contouring, real-time MR motion management, and daily plan adaptation. The clinical and dosimetric benefits associated with prostate SMART remain largely unknown. Methods and Materials: A phase 1 trial of prostate SMART was conducted with primary endpoints of safety and feasibility. An additional cohort of patients similarly treated with prostate SMART were included in the analysis. SMART was delivered to 36.25 Gy in 5 fractions to the prostate ± seminal vesicles using the MRIdian linear accelerator system (ViewRay, Inc). Rates of urinary and gastrointestinal toxic effects and patient-reported outcome measures were assessed. Dosimetric analyses were conducted to evaluate the specific benefits of daily plan adaptation. Results: The cohort included 22 patients (n = 10 phase 1, n = 12 supplemental) treated in 110 fractions. Median follow-up was 7.9 months. Acute grade 2 urinary and gastrointestinal toxic effects were observed in 22.7% and 4.5%, respectively, and 4.5% and 0%, respectively, at last follow-up. No grade 3+ events were observed. Expanded Prostate Cancer Index-26 urinary obstructive scores decreased during SMART (mean, 9.3 points; P = .03) and returned to baseline by 3 months. No other significant changes in patient-reported outcome measures were observed. One-hundred percent of fractions required plan adaptation owing to exceeding organ-at-risk metrics (68%) or suboptimal target coverage (33%) resulting from anatomic changes. Minimum acceptable planning target volume, rectal, bladder, and urethra/bladder neck metrics were violated in 24%, 20%, 24%, and 33% of predicted plans, respectively; 0% of reoptimized plans violated metrics. Underlying causes for deficient dosimetry before reoptimization included changes in bladder filling, seminal vesicle position, prostate volume (median 4.7% increase by fraction 3; range, 0%-56%), and hotspots shifting into urethra/bladder neck. Conclusions: Prostate SMART results in low risk of acute toxic effects with improvements in target and organ-at-risk dosimetry. The clinical benefits resulting from daily plan adaptation, including urethra/bladder neck protection, warrant further investigation.

9.
Int J Radiat Oncol Biol Phys ; 114(5): 941-949, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-35598799

RESUMEN

PURPOSE: Stereotactic body radiation therapy can be an effective treatment for oligometastases. However, safe delivery of ablative radiation is frequently limited by the proximity of mobile organs sensitive to high radiation doses. The goal of this study was to determine the feasibility, safety, and disease control outcomes of stereotactic magnetic resonance-guided adaptive radiation therapy (SMART) in patients with abdominopelvic oligometastases. METHODS AND MATERIALS: We identified 101 patients with abdominopelvic oligometastases, including 20 patients enrolled on phase 1 protocols, who were consecutively treated with SMART on a 0.35T magnetic resonance linear accelerator (MR linac) at a single institution from October 2019 to September 2021. Local control and overall survival were analyzed using the Kaplan-Meier method. RESULTS: Overall, 114 tumors were treated. The most common histology was prostate adenocarcinoma (60 tumors [53.5%]), and 65 sites (57.0%) were centered in the pelvis. Ninety-one sites (79.8%) were treated to 8 Gy × 5, and 49 (43.0%) were treated with breath-hold respiratory gating. Online adaptation resulted in a clinically significant improvement in coverage or organ sparing in 86.6% of delivered fractions. The median time required for adaptation was 24 minutes, and the median time in the treatment room was 58 minutes. With median follow-up of 11.4 months, the 12-month local control was 93% and was higher for prostate adenocarcinoma versus other histologies (100% vs 84%; P = .009). The 12-month overall survival was 96% and was higher for prostate adenocarcinoma versus other histologies (100% vs 91%; P = .046). Three patients (3.0%) developed grade 3 toxic effects (colonic hemorrhage at 3.4 months and urinary tract obstructions at 10.1 and 18.4 months, respectively). CONCLUSIONS: In this study, SMART was feasible, safe, and effective for delivering ablative radiation therapy to abdominopelvic metastases. Adaptive planning was necessary in the large majority of cases. The advantages of SMART warrant its further investigation as a standard option for the treatment of abdominopelvic oligometastases.


Asunto(s)
Adenocarcinoma , Neoplasias de la Próstata , Radiocirugia , Masculino , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Estudios Retrospectivos , Radiocirugia/efectos adversos , Radiocirugia/métodos , Neoplasias de la Próstata/radioterapia , Espectroscopía de Resonancia Magnética , Adenocarcinoma/radioterapia
10.
JCO Clin Cancer Inform ; 6: e2100095, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-35084935

RESUMEN

PURPOSE: Coronary artery calcium (CAC) quantified on computed tomography (CT) scans is a robust predictor of atherosclerotic coronary disease; however, the feasibility and relevance of quantitating CAC from lung cancer radiotherapy planning CT scans is unknown. We used a previously validated deep learning (DL) model to assess whether CAC is a predictor of all-cause mortality and major adverse cardiac events (MACEs). METHODS: Retrospective analysis of non-contrast-enhanced radiotherapy planning CT scans from 428 patients with locally advanced lung cancer is performed. The DL-CAC algorithm was previously trained on 1,636 cardiac-gated CT scans and tested on four clinical trial cohorts. Plaques ≥ 1 cubic millimeter were measured to generate an Agatston-like DL-CAC score and grouped as DL-CAC = 0 (very low risk) and DL-CAC ≥ 1 (elevated risk). Cox and Fine and Gray regressions were adjusted for lung cancer and cardiovascular factors. RESULTS: The median follow-up was 18.1 months. The majority (61.4%) had a DL-CAC ≥ 1. There was an increased risk of all-cause mortality with DL-CAC ≥ 1 versus DL-CAC = 0 (adjusted hazard ratio, 1.51; 95% CI, 1.01 to 2.26; P = .04), with 2-year estimates of 56.2% versus 45.4%, respectively. There was a trend toward increased risk of major adverse cardiac events with DL-CAC ≥ 1 versus DL-CAC = 0 (hazard ratio, 1.80; 95% CI, 0.87 to 3.74; P = .11), with 2-year estimates of 7.3% versus 1.2%, respectively. CONCLUSION: In this proof-of-concept study, CAC was effectively measured from routinely acquired radiotherapy planning CT scans using an automated model. Elevated CAC, as predicted by the DL model, was associated with an increased risk of mortality, suggesting a potential benefit for automated cardiac risk screening before cancer therapy begins.


Asunto(s)
Aprendizaje Profundo , Neoplasias Pulmonares , Calcio , Vasos Coronarios/diagnóstico por imagen , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Estudios Retrospectivos , Factores de Riesgo
11.
Med Phys ; 49(3): 1814-1821, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35090060

RESUMEN

PURPOSE: Internal motion of the larynx can cause normal tissue toxicity and/or tumor underdosage during radiotherapy. MR-guided radiation therapy (MRgRT) provides improved soft-tissue contrast for patient setup and real-time gating of radiation based on cine imaging of tumor motion, potentially making it an advantageous modality for laryngeal treatments. However, there are potential concerns regarding the small target size, proximity to heterogeneous tissue interfaces in the airway that may cause dosimetric errors in the presence of the magnetic field, and uncertainty about the ability of MR-linear accelerator (MR-Linac) systems to visualize and track laryngeal motion. To date, there have been no reports of the use of MRgRT for laryngeal treatments. METHODS: A healthy volunteer was imaged on a ViewRay MRIdian MR-Linac. Organs-at-risk and a laryngeal pseudo target were contoured and used to generate a stereotactic body radiotherapy plan. A custom phantom was created using 3D-printing based on structures delineated on the volunteer images to construct an enclosure containing the target and airway anatomy, with a gap for radiochromic film, and filled with gelatin . The treatment plan was mapped onto the phantom and delivered dose assessed on radiochromic film with global normalization and a 10% dose threshold. A cine MR of the volunteer was acquired to assess the magnitude of larynx motion with speaking and swallowing, and system's ability to gate radiation. RESULTS: A clinically acceptable laryngeal treatment plan and larynx phantom that was MR and computed tomography-visible were successfully created. The delivered dose had good agreement with the treatment plan with a gamma passing rate of 96.5% (3%/2 mm). The MR-Linac was able to visualize, track, and gate larynx motion. CONCLUSIONS: The MRgRT workflow for laryngeal treatments was assessed and performed in preparation for clinical implementation on the MR-Linac, demonstrating that it is feasible to treat laryngeal cancer patients on the MR-Linac.


Asunto(s)
Neoplasias Laríngeas , Laringe , Radioterapia Guiada por Imagen , Voluntarios Sanos , Humanos , Neoplasias Laríngeas/diagnóstico por imagen , Neoplasias Laríngeas/radioterapia , Laringe/diagnóstico por imagen , Imagen por Resonancia Magnética , Aceleradores de Partículas , Fantasmas de Imagen , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/métodos , Tomografía Computarizada por Rayos X
12.
Int J Radiat Oncol Biol Phys ; 112(4): 996-1003, 2022 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-34774998

RESUMEN

PURPOSE: Cardiac toxicity is a well-recognized risk after radiation therapy (RT) in patients with non-small cell lung cancer (NSCLC). However, the extent to which treatment planning optimization can reduce mean heart dose (MHD) without untoward increases in lung dose is unknown. METHODS AND MATERIALS: Retrospective analysis of RT plans from 353 consecutive patients with locally advanced NSCLC treated with intensity modulated RT (IMRT) or 3-dimensional conformal RT. Commercially available machine learning-guided clinical decision support software was used to match RT plans. A leave-one-out predictive model was used to examine lung dosimetric tradeoffs necessary to achieve a MHD reduction. RESULTS: Of all 232 patients, 91 patients (39%) had RT plan matches showing potential MHD reductions of >4 to 8 Gy without violating the upper limit of lung dose constraints (lung volume [V] receiving 20 Gy (V20 Gy) <37%, V5 Gy <70%, and mean lung dose [MLD] <20 Gy). When switching to IMRT, 75 of 103 patients (72.8%) had plan matches demonstrating improved MHD (average 2.0 Gy reduction, P < .0001) without violating lung constraints. Examining specific lung dose tradeoffs, a mean ≥3.7 Gy MHD reduction was achieved with corresponding absolute increases in lung V20 Gy, V5 Gy, and MLD of 3.3%, 5.0%, and 1.0 Gy, respectively. CONCLUSIONS: Nearly 40% of RT plans overall, and 73% when switched to IMRT, were predicted to have reductions in MHD >4 Gy with potentially clinically acceptable tradeoffs in lung dose. These observations demonstrate that decision support software for optimizing heart-lung dosimetric tradeoffs is feasible and may identify patients who might benefit most from more advanced RT technologies.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Radioterapia de Intensidad Modulada , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Humanos , Neoplasias Pulmonares/radioterapia , Aprendizaje Automático , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/efectos adversos , Radioterapia de Intensidad Modulada/métodos , Estudios Retrospectivos , Programas Informáticos
14.
J Am Geriatr Soc ; 69(3): 779-784, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33395498

RESUMEN

BACKGROUND/OBJECTIVE: Ineffective interdisciplinary communication has negative impacts on patient outcomes. The use of regular structured interdisciplinary bedside rounds (SIBR), where each patient interaction lasts 3-5 minutes, is a model of care that improves interdisciplinary communication. We evaluated the impact of SIBR on in-hospital falls. DESIGN: Prospective before-after study of older people hospitalized with acute illness. SETTING: Two side-by-side aged care wards in a university hospital in Sydney, Australia. PARTICIPANTS: A total of 3,673 consecutive inpatients of mean age 83.8 ± 7.7 years, with 1,703 before SIBR compared with 1,970 after SIBR. No patients were excluded from potential participation. INTERVENTION: Twice-weekly SIBR. MEASUREMENTS: Falls data were manually extracted from a mandatory institutional incident reporting database. Medical diagnoses were based on the Australian Refined Diagnosis Related Groups classification system. Injuries due to falls were corroborated using the institutional electronic medical record (Cerner PowerChart). Generalized estimating equations were used to evaluate the incidence rate ratio (IRR) of falls and fall-related injuries. A negative binomial distribution and a logarithmic link function were used to linearize regression equations. RESULTS: After SIBR, there were 7.4 falls per 1,000 occupied bed days (OBD), compared with 10.6 falls per 1,000 OBD before SIBR (P < .001). The implementation of SIBR reduced falls (IRR = 0.67, 95% CI = 0.52-0.85), after adjusting for age, gender, cognitive impairment, behavioral and psychological symptoms of dementia, deconditioning and frailty, but not fall-related injuries (IRR = 0.79, 95% CI = 0.52-1.20). CONCLUSION: This study is the first to investigate the effect of SIBR on in-hospital falls. It provides evidence that a sustainable, twice-weekly intervention is associated with a reduction in falls. It has the potential to be used in other settings where falls are frequent.


Asunto(s)
Accidentes por Caídas/prevención & control , Comunicación Interdisciplinaria , Accidentes por Caídas/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Disfunción Cognitiva/epidemiología , Estudios Controlados Antes y Después , Bases de Datos Factuales , Femenino , Humanos , Masculino , Estudios Prospectivos
15.
Artículo en Inglés | MEDLINE | ID: mdl-33305025

RESUMEN

PURPOSE: MR-linacs (MRLs) have enabled the use of stereotactic magnetic resonance (MR) guided online adaptive radiotherapy (SMART) across many cancers. As data emerges to support SMART, uncertainty remains regarding optimal technical parameters, such as optimal patient positioning, immobilization, image quality, and contouring protocols. Prior to clinical implementation of SMART, we conducted a prospective study in healthy volunteers (HVs) to determine optimal technical parameters and to develop and practice a multidisciplinary SMART workflow. METHODS: HVs 18 years or older were eligible to participate in this IRB-approved study. Using a 0.35 T MRL, simulated adaptive treatments were performed by a multi-disciplinary treatment team in HVs. For each scan, image quality parameters were assessed on a 5-point scale (5 = extremely high, 1 = extremely poor). Adaptive recontouring times were compared between HVs and subsequent clinical cases with a t-test. RESULTS: 18 simulated treatments were performed in HVs on MRL. Mean parameters for visibility of target, visibility of nearby organs, and overall image quality were 4.58, 4.62, and 4.62, respectively (range of 4-5 for all measures). In HVs, mean ART was 15.7 min (range 4-35), comparable to mean of 16.1 (range 7-33) in the clinical cases (p = 0.8963). Using HV cases, optimal simulation and contouring guidelines were developed across a range of disease sites and have since been implemented clinically. CONCLUSIONS: Prior to clinical implementation of SMART, scans of HVs on an MRL resulted in acceptable image quality and target visibility across a range of organs with similar ARTs to clinical SMART. We continue to utilize HV scans prior to clinical implementation of SMART in new disease sites and to further optimize target tracking and immobilization. Further study is needed to determine the optimal duration of HV scanning prior to clinical implementation.

16.
Med Phys ; 47(11): 5490-5495, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32966609

RESUMEN

BACKGROUND: Treatment misadministration during high dose rate (HDR) brachytherapy is mainly caused due to gross errors in incorrect manual entry of catheter length and manual connection of hardware. The probability of these errors increases with increasing complexity of a surface applicator. A simple, real-time visual verification method was developed using a scintillator to enhance quality assurance (QA) measures for HDR surface brachytherapy and thus reduce manual errors and improve patient safety. MATERIALS AND METHODS: Scintillation markers were fabricated from cerium-doped lutetium yttrium orthosilicate (LYSO) embedded in a polymer compound to form 5-mm diameter markers. To verify catheter-transfer tube connections, markers were attached to each channel of a Freiburg flap and irradiated with an 192 Ir source. To determine if the source reached the edge of a target, markers were placed along the periphery. The HDR source was visually tracked by following the illumination from the markers. The response of the markers was also verified in the presence of thermoplastic material overlaid on the Freiburg applicator. RESULTS: Scintillation markers emitted intense blue visible light upon irradiation when the HDR source was beneath the marker, verifying the source's presence in the correct catheter. The signal was clearly visible even when the marker was placed on top of the thermoplastic material covering the Freiburg Flap. Crosstalk from adjacent catheters was <50% of the maximum light intensity. CONCLUSION: Scintillation markers and paint were developed to successfully meet the challenge of visually tracking of HDR source during brachytherapy by surface applicators. This direct visualization of source allows real-time catheter verification during treatment, and correct superficial target coverage, thus preventing a medical event. It can easily be integrated into pre-existing QA program.


Asunto(s)
Braquiterapia , Catéteres , Humanos , Fenómenos Físicos , Dosificación Radioterapéutica , Piel
17.
Nat Rev Clin Oncol ; 17(12): 771-781, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32843739

RESUMEN

Artificial intelligence (AI) has the potential to fundamentally alter the way medicine is practised. AI platforms excel in recognizing complex patterns in medical data and provide a quantitative, rather than purely qualitative, assessment of clinical conditions. Accordingly, AI could have particularly transformative applications in radiation oncology given the multifaceted and highly technical nature of this field of medicine with a heavy reliance on digital data processing and computer software. Indeed, AI has the potential to improve the accuracy, precision, efficiency and overall quality of radiation therapy for patients with cancer. In this Perspective, we first provide a general description of AI methods, followed by a high-level overview of the radiation therapy workflow with discussion of the implications that AI is likely to have on each step of this process. Finally, we describe the challenges associated with the clinical development and implementation of AI platforms in radiation oncology and provide our perspective on how these platforms might change the roles of radiotherapy medical professionals.


Asunto(s)
Inteligencia Artificial , Neoplasias/radioterapia , Oncología por Radiación/tendencias , Humanos , Medicina de Precisión/tendencias
18.
Vet Radiol Ultrasound ; 61(3): 312-321, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32125022

RESUMEN

The objectives of this retrospective, observational study were to characterize the anatomical features of the cisterna chyli (CC) in a cohort of dogs diagnosed with idiopathic chylothorax that underwent CT lymphangiography (CTLa), and to evaluate the feasibility of computer-assisted design (CAD) software to quantify volumetric measurements of the CC. Twenty-three client-owned dogs with idiopathic chylothorax were included. Additionally, CTLa was performed in three canine cadavers to assess the ability of CAD software to accurately acquire volumetric measurements. Injection sites, attenuation values, anatomic location, dimensions, and aortic diameter to CC ratio (Ao:CC) were recorded. Video records of video-assisted thoracic surgery (VATS) thoracic duct ligation (TDL) were reviewed in eight out of 23 dogs to compare operative and CTLa findings. The CC was dorsal and right-sided in 18 out of 23 dogs, located between L1 and L4 in 21 dogs, and extended as far cranially as T11 in two dogs. The median measurements for length, height, and width were 150.0, 5.5, and 13.3 mm, respectively. Median total volume was 1.82 mL. Median volumes to the right and left of the aorta were 1.46 and 0.49 mL, respectively (P = .014). Median total CC volume to body weight ratio (CC:bw) was 0.07 mL/kg. The presence of an intrathoracic CC was observed intraoperatively in six out of eight cases that underwent VATS TDL. Findings supported the use of CTLa and CAD as feasible methods for characterizing the CC in dogs diagnosed with chylothorax. These methods may facilitate interventional planning involving the CC such as embolization.


Asunto(s)
Quilotórax/veterinaria , Diseño Asistido por Computadora , Enfermedades de los Perros/diagnóstico por imagen , Linfografía/veterinaria , Programas Informáticos , Tomografía Computarizada por Rayos X/veterinaria , Animales , Cadáver , Quilotórax/diagnóstico por imagen , Enfermedades de los Perros/patología , Perros , Femenino , Ligadura , Linfografía/métodos , Masculino , Estudios Retrospectivos , Conducto Torácico , Tomografía Computarizada por Rayos X/métodos
19.
Vet Radiol Ultrasound ; 61(6): E55-E59, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29938862

RESUMEN

An 8-year-old, spayed female, domestic short haired cat, with diabetes mellitus, was presented to the University of Florida Veterinary Medical Center for an acute onset of vomiting and inappetence. Abdominal radiographs showed mild retroperitoneal effusion and asymmetric left-sided renomegaly. Subsequently, on abdominal ultrasound, a hypoechoic left ureteral mass with left hydronephrosis and hydroureter was identified. An abdominal computed tomography revealed a heterogeneously contrast-enhancing mass circumferentially surrounding the mid to distal left ureter, mild retroperitoneal effusion, left-sided hydronephrosis and hydroureter, and a distally located ureteral calculus at the level of the ureterovesicular junction. The patient was diagnosed with left-sided pyogranulomatous ureteritis via surgical biopsy and histopathology.


Asunto(s)
Enfermedades de los Gatos/diagnóstico por imagen , Complicaciones de la Diabetes/veterinaria , Granuloma/veterinaria , Hidronefrosis/veterinaria , Neoplasias Ureterales/veterinaria , Animales , Gatos , Diagnóstico Diferencial , Femenino , Granuloma/complicaciones , Granuloma/diagnóstico por imagen , Hidronefrosis/complicaciones , Hidronefrosis/diagnóstico por imagen , Radiografía Abdominal/veterinaria , Tomografía Computarizada por Rayos X/veterinaria , Ultrasonografía/veterinaria , Neoplasias Ureterales/complicaciones , Neoplasias Ureterales/diagnóstico por imagen , Vómitos/etiología , Vómitos/veterinaria
20.
Complement Ther Clin Pract ; 36: 18-28, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31383437

RESUMEN

BACKGROUND: Although childhood cancer mortality rates are decreasing, intensive treatment modalities and missed school days may leave childhood cancer patients psychologically and socially vulnerable. Children with cancer often have increased anxiety, lower levels of self-esteem, and higher rates of depression, all of which may impair their psychosocial wellbeing. Specialized camps for children with cancer are becoming increasingly popular, as they provide a stress-free, outdoor environment in which children are able to interact with individuals similar to themselves, while experiencing the joys of a "normal childhood." OBJECTIVE: The aim of this review was to explore how camp participation impacts the psychosocial wellbeing of childhood cancer patients and survivors. METHODS: Six databases (MEDLINE, PsychINFO, EMBASE, CINHAL, Sociological Abstracts, Social Sciences Citation Index) were systematically searched for English literature published between 2007 and 2018. The search generated 1707 titles, and after being evaluated for relevance, 18 articles met the inclusion criteria. A thematic analysis was conducted. RESULTS: A variety of camp programs and methodologies were employed among the studies. Camp participation led to improved social health, followed by enhanced constructions of the self, quality of life, sense of normalcy, and attitude. CONCLUSION: This review demonstrates the potential ability of camp to buffer psychosocial losses for children affected by cancer. Addressing limitations, such as the lack of child-centered methodologies employed in camp settings, may not only help to guide future research on therapeutic recreation experiences for children with cancer, but also expand the evidence base for children living with other chronic illnesses and disabilities.


Asunto(s)
Acampada , Supervivientes de Cáncer/psicología , Neoplasias , Terapia Recreativa , Adolescente , Niño , Femenino , Humanos , Masculino , Neoplasias/psicología , Neoplasias/rehabilitación
SELECCIÓN DE REFERENCIAS